Water softening for households - Professional / TAPWORKS
Professional is one of the latest lines of appliances for water treatment and softening based on ion exchange, especially recommended for households.
Advantages of the appliances
- electronic and logical volumetric steering;
- high-performance filtration bed;
- digital panel with LCD display;
- continuous control of an appliance's working parameters
(also with the help of EASE/ESP modem connections);
- proportional regeneration of ion-exchange filtration bed (dependent on resin consumption level);
- low exploitation costs (lowered water and salt amounts needed
for regeneration of a filtration bed);
- 24-hour memory support in case of power supply break;
- constant index of intensity of treated water flow.
|
NSC 11 ED NSC 17 ED
|
|
 |
|
 |
Parameter |
Unit |
NSC 11 ED |
NSC 17 ED |
Capacity of bed |
dm3 |
11 |
17 |
|
Type of bed |
- |
cation-exchanger strongly acid |
|
Maximum momentary flow intensity |
m3/h |
0,9 |
1,3 |
|
Average ion-exchange capacity |
m3x0f |
70 |
125 |
|
Maximum 24-hour productivity in automatic mode at a residual hardness <1 0 dH and raw water hardness:
- 10 0 dH
- 14 0 dH
- 18 0 dH
- 23 0 dH
|
- |
3,9 2,8 2,2 1,7 |
7,0 5,0 3,9 3,1 |
|
Maximum total level of Fe++ i Mn++ |
ppm |
2,2 without warranty of removal |
|
Activation of regeneration |
- |
with use of capacity based on prediction with forced regeneration system |
|
Regeneration system |
- |
countercurrent |
|
Preparation of brine |
- |
from soft water |
|
Maximum salt consumption for one regeneration at maximum bed consumption |
kg |
1,7 |
3,2 |
|
Strictly required type of regeneration salt |
- |
regeneration salt in form of tablets PN 86/84081/01/02; DIN 19 604 |
|
Maximum momentary flow intensity of water needed for regeneration |
m3/h dm3/min |
0,55 9,20 |
0,60 11,00 |
|
Approximate water consumption for one regeneration at maximum bed consumption |
dm3 |
60 - 80 |
85 - 115 |
|
Time of regeneration |
h:min |
ok. 1:00 |
ok. 2:00 |
|
Minimum and maximum water temperature |
0 C |
4 - 49 |
|
Power consumption - during operation - during regeneration |
W W |
<3 <15 |
|
Maximum working pressure during the flow |
bar |
1,4 |
|
Maximum working pressure |
bar |
8 |
|
Functions of steering system
Type of steering |
- |
electronic |
electronic, logic based on prediction |
Programming and display of a present time |
- |
yes |
|
Programming of regeneration starting hour |
- |
yes |
|
Programming of raw water hardness |
- |
yes 1 - 50 0 dH |
yes |
|
Programming of economical regeneration mode |
- |
no |
no |
|
Immediate regeneration |
- |
yes |
|
Regeneration at the nearest programmed hour |
- |
yes |
|
Bed cleaning in case of usage of water of increased suspension content |
- |
no |
no |
|
Automatic regeneration in case of lack of water consumption |
- |
yes |
yes programmed for 7 days |
|
Indicator of treated water flow |
- |
yes |
|
Memory of starting date |
- |
yes |
|
Regeneration counter |
- |
yes |
|
Measurements
Automatic regeneration in case of lack of water consumption |
cm |
65 x 30 x 48 |
106 x 30 x 48 |
|
NSC 25 ED NSC 70 ED
|
|
 |
|
 |
Parameter |
Unit |
NSC 25 ED |
NSC 70 ED |
Capacity of bed |
dm3 |
20 |
60 |
|
Type of bed |
- |
kationit silnie kwaśny |
|
Maximum momentary flow intensity |
m3/h |
2,5 |
3,6 |
|
Average ion-exchange capacity |
m3x0f |
150 |
395 |
|
Maximum 24-hour productivity
in automatic mode at a residual
hardness <1 0 dH and raw water hardness:
- 10 0 dH
- 14 0 dH
- 18 0 dH
- 23 0 dH
|
- |
8,4 6 4,7 3,7 |
22,2 15,9 12,3 9,7 |
|
Maximum total level of Fe++ i Mn++ |
ppm |
2,2 without warranty of removal |
|
Activation of regeneration |
- |
nwith use of capacity based on prediction with forced regeneration system |
|
Regeneration system |
- |
countercurrent |
|
Preparation of brine |
- |
from soft water |
|
Maximum salt consumption for one regeneration at maximum bed consumption |
kg |
4 |
9 |
|
Strictly required type of regeneration salt |
- |
regeneration salt in form of tablets PN 86/84081/01/02; DIN 19 604 |
|
Maximum momentary flow intensity of water needed for regeneration |
m3/h dm3/min |
0,68 11,40 |
0,69 11,50 |
|
Approximate water consumption for one regeneration at maximum bed consumption |
dm3 |
120 - 150 |
280 - 430 |
|
Time of regeneration |
h:min |
ok. 2:00 |
ok. 3:30 |
|
Minimum and maximum water temperature |
0 C |
4 - 49 |
|
Power consumption - during operation - during regeneration |
W W |
<3 <15 |
|
Maximum working pressure during the flow |
bar |
1,4 |
|
Maximum working pressure |
bar |
8 |
|
Functions of steering system
Type of steering |
- |
electronic |
electronic |
Programming and display of a present time |
- |
yes |
|
Programming of regeneration starting hour |
- |
yes |
|
Programming of raw water hardness |
- |
yes 1 - 95 0 dH |
yes 1 - 120 0 dH |
|
Programming of economical regeneration mode |
- |
yes |
no |
|
Immediate regeneration |
- |
yes |
|
Regeneration at the nearest programmed hour |
- |
yes |
|
Bed cleaning in case of usage of water of increased suspension content |
- |
no |
yes |
|
Automatic regeneration in case of lack of water consumption |
- |
no |
yes |
|
Indicator of treated water flow |
- |
yes |
|
Memory of starting date |
- |
yes |
|
Regeneration counter |
- |
yes |
|
Measurements
Automatic regeneration in case of lack of water consumption |
cm |
123 x 47 x 47 |
163 x 79 x 46 |
|
|
|
|