Softeners - TAPWORKS
Professional is one of the latest lines of appliances for water treatment and softening based on ion exchange, especially recommended for households.
Advantages of the appliances
- electronic and logical volumetric steering;
- high-performance filtration bed;
- digital panel with LCD display;
- continuous control of an appliance's working parameters
(also with the help of EASE/ESP modem connections);
- proportional regeneration of ion-exchange filtration bed (dependent on resin consumption level);
- low exploitation costs (lowered water and salt amounts needed
for regeneration of a filtration bed);
- 24-hour memory support in case of power supply break;
- constant index of intensity of treated water flow.
|
NSC 11 ED NSC 17 ED
|
|
 |
|
 |
Parameter |
Unit |
NSC 11 ED |
NSC 17 ED |
Capacity of bed |
dm3 |
11 |
17 |
|
Type of bed |
- |
cation-exchanger strongly acid |
|
Maximum momentary flow intensity |
m3/h |
0,9 |
1,3 |
|
Average ion-exchange capacity |
m3x0f |
70 |
125 |
|
Maximum 24-hour productivity in automatic mode at a residual hardness <1 0 dH and raw water hardness:
- 10 0 dH
- 14 0 dH
- 18 0 dH
- 23 0 dH
|
- |
3,9 2,8 2,2 1,7 |
7,0 5,0 3,9 3,1 |
|
Maximum total level of Fe++ i Mn++ |
ppm |
2,2 without warranty of removal |
|
Activation of regeneration |
- |
with use of capacity based on prediction with forced regeneration system |
|
Regeneration system |
- |
countercurrent |
|
Preparation of brine |
- |
from soft water |
|
Maximum salt consumption for one regeneration at maximum bed consumption |
kg |
1,7 |
3,2 |
|
Strictly required type of regeneration salt |
- |
regeneration salt in form of tablets PN 86/84081/01/02; DIN 19 604 |
|
Maximum momentary flow intensity of water needed for regeneration |
m3/h dm3/min |
0,55 9,20 |
0,60 11,00 |
|
Approximate water consumption for one regeneration at maximum bed consumption |
dm3 |
60 - 80 |
85 - 115 |
|
Time of regeneration |
h:min |
ok. 1:00 |
ok. 2:00 |
|
Minimum and maximum water temperature |
0 C |
4 - 49 |
|
Power consumption - during operation - during regeneration |
W W |
<3 <15 |
|
Maximum working pressure during the flow |
bar |
1,4 |
|
Maximum working pressure |
bar |
8 |
|
Functions of steering system
Type of steering |
- |
electronic |
electronic, logic based on prediction |
Programming and display of a present time |
- |
yes |
|
Programming of regeneration starting hour |
- |
yes |
|
Programming of raw water hardness |
- |
yes 1 - 50 0 dH |
yes |
|
Programming of economical regeneration mode |
- |
no |
no |
|
Immediate regeneration |
- |
yes |
|
Regeneration at the nearest programmed hour |
- |
yes |
|
Bed cleaning in case of usage of water of increased suspension content |
- |
no |
no |
|
Automatic regeneration in case of lack of water consumption |
- |
yes |
yes programmed for 7 days |
|
Indicator of treated water flow |
- |
yes |
|
Memory of starting date |
- |
yes |
|
Regeneration counter |
- |
yes |
|
Measurements
Automatic regeneration in case of lack of water consumption |
cm |
65 x 30 x 48 |
106 x 30 x 48 |
|
Technical data of the NSC 30 ED
|
|
 |
Control |
Fully automatic control (elektronic, logical based upon prognosis) |
|
Resin type |
Strongly sour kationite |
|
Average ionexchange capacity |
180 m3x°f |
|
Efficiency between regeneration in auto mode by the water hardness 320 mgCaCO3/dm3 |
5,6 m3 5 600 dm3 |
|
Regeneration launch |
By volume based upon prognosis |
|
Regeneration system |
Against current |
|
Brine preparation |
Out of soft water |
|
Aprox. salt consumption on 1 regeneration by used out resin |
4,5 kg |
|
Type of salt (Regeneration) |
Salt tablets PN 86/C-84081/01/02; DIN 19 604 |
|
Max momentum intensity of water flow necessery in regeneration process |
11,4 dm3/min |
|
Approximate consumption of water for a regeneration |
140 - 160 dm3 |
|
Regen. duration |
Approx 120 min |
|
Working temp. range of water |
4 - 49 oC |
|
Minimal working bar (pressure) |
1,4 bar |
|
Max. working pressure |
8,0 bar |
|
Power consumption during work |
< 3 W |
|
Power consumption during regener. |
< 15 W |
|
Size (height x wide x depth) |
123 cm x 47 cm x 47 cm |
|
Control system function |
NSC 30 ED |
Hour of regeneration start |
YES |
|
Raw water hardness programming |
YES (86°dH) |
|
Eco regeneration process |
YES |
|
Nearest programmed hour regeneration |
YES |
|
Resin cleaning program by using strongly contaminated water |
YES |
|
Auto regeneration in case of problems with water intake |
YES (1-7 days possible program mode) |
|
Clean water flow indicator |
YES |
|
Date of initial launch memory |
YES |
|
Regeneration count system |
YES |
|
Additional equipement included in price |
NSC 30 ED |
Contaminated flush out water outlet hose |
YES |
|
Mounting assemble details |
NO |
|
+ bypass with hardness regulator |
NO |
|
Adjustment picture
|
Technical data of the NSC 70 ED
|
|
 |
Type of bed |
- |
kationit silnie kwaśny |
|
Maximum momentary flow intensity |
m3/h |
3,6 |
|
Average ion-exchange capacity |
m3x0f |
395 |
|
Maximum 24-hour productivity
in automatic mode at a residual
hardness <1 0 dH and raw water hardness:
- 10 0 dH
- 14 0 dH
- 18 0 dH
- 23 0 dH
|
- |
22,2 15,9 12,3 9,7 |
|
Maximum total level of Fe++ i Mn++ |
ppm |
2,2 without warranty of removal |
|
Activation of regeneration |
- |
nwith use of capacity based on prediction with forced regeneration system |
|
Regeneration system |
- |
countercurrent |
|
Preparation of brine |
- |
from soft water |
|
Maximum salt consumption for one regeneration at maximum bed consumption |
kg |
9 |
|
Strictly required type of regeneration salt |
- |
regeneration salt in form of tablets PN 86/84081/01/02; DIN 19 604 |
|
Maximum momentary flow intensity of water needed for regeneration |
m3/h dm3/min |
0,69 11,50 |
|
Approximate water consumption for one regeneration at maximum bed consumption |
dm3 |
280 - 430 |
|
Time of regeneration |
h:min |
ok. 3:30 |
|
Minimum and maximum water temperature |
0 C |
4 - 49 |
|
Power consumption - during operation - during regeneration |
W W |
<3 <15 |
|
Maximum working pressure during the flow |
bar |
1,4 |
|
Maximum working pressure |
bar |
8 |
|
Functions of steering system
Type of steering |
- |
electronic |
Programming and display of a present time |
- |
yes |
|
Programming of regeneration starting hour |
- |
yes |
|
Programming of raw water hardness |
- |
tak 1 - 120 0 dH |
|
Programming of economical regeneration mode |
- |
no |
|
Immediate regeneration |
- |
yes |
|
Regeneration at the nearest programmed hour |
- |
yes |
|
Bed cleaning in case of usage of water of increased suspension content |
- |
yes |
|
Automatic regeneration in case of lack of water consumption |
- |
yes |
|
Indicator of treated water flow |
- |
yes |
|
Memory of starting date |
- |
yes |
|
Regeneration counter |
- |
yes |
|
Measurements |
cm |
163 x 79 x 46 |
|
|
|
|